📝 Cost

Electricity Bill Calculation: From T1, T2, T3 Registers to the Total

6S Teknoloji · 08.11.2026 · 6 min read

Electricity Bill Calculation: From T1, T2, T3 Registers to the Total — 6S Teknoloji

An electricity bill is a handful of multiplications and additions from meter index to amount due; yet without knowing the line items the bill becomes unreadable. This article explains how an electricity bill is calculated, how the T1, T2, T3 meter registers turn into money, and which consumption profile benefits from a time-of-use tariff. Unit prices in the example are illustrative only; always take the current tariff from your distribution company's published table.

Main line items of the bill

  • Energy charge: kWh consumed × unit energy price. One price on a single-rate tariff, a separate price per band on time-of-use.
  • Distribution charge: a per-kWh fee for using the grid.
  • Reactive energy charge: a penalty added when the inductive or capacitive reactive ratio exceeds the limit (industrial and commercial customers).
  • Demand excess charge: applied when contracted power is exceeded.
  • Taxes and levies: VAT and other statutory items calculated on the subtotal.

The T1, T2, T3 bands

In the Turkish time-of-use tariff the day is split into three bands: T1 day 06:00–17:00, T2 peak 17:00–22:00, T3 night 22:00–06:00. The meter keeps a separate register for each band (1.8.1, 1.8.2, 1.8.3). Peak is the most expensive, night the cheapest. See our time-of-use tariff article for selection rules.

Worked example, step by step

Assume a workshop with the following monthly band consumption and hypothetical unit prices (prices are illustrative):

BandConsumption (kWh)Unit price (₺/kWh, example)Energy charge (₺)
T1 day6,0003.0018,000
T2 peak2,5004.8012,000
T3 night1,5001.802,700
Total10,000—32,700
  • Distribution charge: 10,000 kWh × 1.20 ₺ (example) = 12,000 ₺
  • Subtotal: 32,700 + 12,000 = 44,700 ₺
  • Taxes and levies (example 20%): 8,940 ₺
  • Bill total: about 53,640 ₺

The same 10,000 kWh on a single-rate tariff at, say, 3.30 ₺ would give an energy charge of 33,000 ₺. In this example time-of-use is 300 ₺ cheaper; a larger peak share would reverse the result.

When does time-of-use pay off?

The decision rule is the share of the peak band in total consumption. Facilities running at night and weekends, cold stores and continuous production lines have a high T3 share and benefit from time-of-use. Shopping centres and restaurants whose activity concentrates after 17:00 have a large T2 share and may be safer on single-rate. At least three months of hourly consumption data are needed to decide.

Common mistakes on the bill

  • Forgetting the multiplier: on CT-connected meters the index difference must be multiplied by the CT ratio before pricing.
  • Ignoring the reactive line: the energy charge may be right while the reactive penalty inflates the total; see reactive energy penalty.
  • Mixing up band hours: 1.8.1 is day, 1.8.2 peak, 1.8.3 night.
  • Using an outdated tariff: tariffs are revised periodically.

Verifying the bill against meter data

The 6S Teknoloji platform multiplies the T1-T2-T3 index differences read from the meter by the tariff table and produces an estimated bill before the month closes; when the actual bill is entered it reconciles line by line. Because the reactive ratio and demand are watched on the same screen, penalty items stop being a surprise. In buildings with sub-tenants a separate bill is produced per meter. See the billing solution page for details.

Related Content

Multi-Time Tariff (T1/T2/T3) ExplainedAutomated Energy Billing — Time-of-UseWhat Is a Reactive Energy Penalty? 2026 Ratesenergy monitoring softwareenergy cost projectioncompatible meters and analysersHow to Read an Electricity Meter Step by StepWhat Is an Energy Analyzer? Buyer's Guide

FAQ

What are the T1, T2, T3 electricity hours?
In Türkiye T1 (day) is 06:00–17:00, T2 (peak) 17:00–22:00 and T3 (night) 22:00–06:00. The meter stores each band's index separately in registers 1.8.1, 1.8.2 and 1.8.3.
How is the electricity bill amount calculated?
Each band's kWh is multiplied by its unit price, the distribution charge and any reactive or demand excess charges are added, and taxes and levies are applied to the subtotal. On CT-connected meters the kWh is first multiplied by the meter multiplier.
Is a time-of-use tariff right for everyone?
No. It pays off where the night (T3) share is high; businesses with a large peak (T2) share may be cheaper on single-rate. Compare both tariffs on at least three months of hourly consumption data before deciding.

Monitor Your Facility with 6S Teknoloji

See 6S Teknoloji at Your Facility

Explore the system with your own data in a demo session.