Every Device, One Platform

From Modbus to M-Bus, from BACnet to OCPP and LoRaWAN — 6S Teknoloji speaks the industrial protocols widely used in the field.

Supported Communication Protocols

Modbus TCP

Active

The most widely used industrial protocol. The vast majority of energy analyzers, UPS units, generators and inverters support it. Reading interval is configured per device.

Industrial energy analyzer, UPS and generator support · ready register templates

Modbus RTU

Active

Runs over an RS-485 serial line. Common for legacy meters and control panels. Integration via a USB-RS485 converter or an RS485-Ethernet gateway.

RS-485 · Baud: 9600/19200 · Parity: None/Even · Gateway-based connection

M-Bus TCP

Active

The standard protocol for water, heat and natural gas meters. Used in meters integrated with infrastructures such as İSKİ, İGDAŞ and similar utilities.

M-Bus TCP gateway support for water, heat and natural gas meters

MQTT / TLS

Active

The transport layer between the field agent and the central platform. Secure delivery with QoS 1, persistent session and TLS 1.3 encryption.

Secure MQTT connection with TLS 1.3 encryption

BACnet/IP

Active

A protocol widely used in building management systems (BMS). VRV/VRF indoor and outdoor units and BMS points are read through the field agent; HVAC data is monitored on the same platform as energy data.

BACnet/IP · VRV/VRF indoor/outdoor units · BMS point reading

OCPP 1.6-J / 2.0.1

Active

EV charging stations connect directly to the platform's OCPP central system (CSMS); no field agent is needed. Charging sessions and energy consumption are monitored.

OCPP 1.6-J and 2.0.1 · WebSocket · direct connection without an agent

LoRaWAN

Active

Wireless LoRaWAN sensors are read through a gateway: CO₂ and indoor air quality, window contact and room controller data. For areas where cabling is difficult.

LoRaWAN gateway · CO₂ / indoor air quality · window contact · room controller

DSE (Deep Sea Electronics)

Active

DSE generator and mains controllers are read: running status, voltage, current, power, fuel and run hours. Generator start-ups are monitored alongside energy data.

DSE GenComm · Modbus TCP · generator / mains modules
✓ ISO 50001 Compliant Reporting ✓ TLS 1.3 Encrypted MQTT ✓ Brand-Independent Integration ✓ Zero Data Loss Architecture

Upstream System Integrations

Combine your energy data with your enterprise systems. Instead of an off-the-shelf connector, the link is set up within the project scope to fit your needs.

ERP and other systems

Connections to your accounting, maintenance management and reporting systems are set up together with you within the project scope, via REST API or Modbus. Scope and data flow are defined jointly on request.

Data Source Integrations

Combine field device measurements with distributor and enterprise data sources. All portal connections run with your official account, within the scope you authorise.

BEDAŞ OSOS

Active

The distribution company's official meter indexes flow directly into the platform. Your main-meter consumption is checked against field measurements; invoice reconciliation relies on the distributor's own data, not estimates.

Distributor meter index · invoice reconciliation · your official account, authorised scope

İGDAŞ AVE

Active

Your natural gas consumption is retrieved daily from the distributor's main-meter measurement on the AVE portal. Processed with the K coefficient and calorific value, your m³ and kWh costs are calculated correctly.

Daily gas measurement · K coefficient + calorific value · your official account, authorised scope

EPİAŞ Transparency

Active

The price components of free-consumer electricity cost (PTF, YEKDEM) are fetched automatically from the EPİAŞ Transparency Platform. Invoice verification and cost projection run on current market data.

PTF + YEKDEM price components · invoice verification · open data platform

HIS (HBYS)

Active

In hospital projects, room and bed occupancy is retrieved automatically from the hospital information system, normalised and correlated with energy consumption. The normalised occupancy is passed to the building management system (BMS) via a Modbus TCP server; occupancy is also an input to budget forecasting.

Room/bed occupancy · normalisation · Modbus TCP hand-off to BMS · forecasting input

Weather Data

Active

Hourly weather data and a 90-day seasonal outlook are retrieved automatically. The effect of temperature on consumption is separated out; budget forecasting and consumption normalisation account for weather conditions.

Hourly weather · 90-day seasonal · forecasting and normalisation input

Integration Questions

Send us your device's technical documentation and register map. We can develop a driver and add it to the system within 2–4 weeks. First review the current devices page: the verified device templates are listed there.
Field devices require the agent; distributor portals (OSOS/AVE) and OCPP charging stations connect without an agent. On site, device reading, queue management and local buffering during connection outages run through the field agent; no data is deleted until delivery is acknowledged.
Yes. REST API and MQTT feed access are available with enterprise licenses. For OpenAPI documentation, write to info@6steknoloji.com.

Shall we add your device?

Share the register map and protocol document, and the driver will be ready within 2–4 weeks.

Request Integration →

See 6S Teknoloji at Your Facility

Explore the system with your own data in a demo session.