⚡ Modbus TCP Integration Guide

Schneider Electric PM5350

Schneider Electric PowerLogic PM5350 Multifunction Power Meter — Real-time power, energy and alarm monitoring via Modbus TCP protocol with 6S Teknoloji.

All Devices →

What Data Do We Read?

Phase A Voltage (V-N)V
Phase B Voltage (V-N)V
Phase C Voltage (V-N)V
Phase A CurrentA
Phase B CurrentA
Phase C CurrentA
Total Active PowerkW
Total Reactive PowerkVAr
Total Apparent PowerkVA
Total Power Factor-
Active Energy ImportkWh
Reactive Energy InductivekVArh

How to Connect to 6S Teknoloji

1

Physical Connection

Connect the device to the RS-485 or Ethernet network. Configure Slave ID and baud rate from the device front panel or web interface.

2

Add Device in 6S Teknoloji

From the 6S web panel click "New Device". Select Schneider Electric PM5350 from the template list — the register map loads automatically.

3

Live Monitoring

The Field Agent tests the connection; the first readings appear on the dashboard shortly. Alarm thresholds are configured.

What Can You Monitor?

  • Three-phase voltage, current, power and power factor
  • Active / reactive / apparent energy (import/export)
  • THD (Total Harmonic Distortion) per phase
  • Peak demand (kW, kVA) with timestamp
  • Min/max/average voltage and current
  • Frequency monitoring (Hz)
  • EPDK reactive penalty threshold warning
  • Phase imbalance alarm

Frequently Asked Questions

Which Modbus function codes does the PM5350 support?
The PM5350 supports reading Holding and Input registers over Modbus TCP and integrates directly with 6S Teknoloji; connection parameters are filled in automatically by the device template.
Can the PM5350 be used for EPDK reactive penalty tracking?
Yes. 6S Teknoloji records the PM5350's kVAr readings at 15-minute granularity and compares the cumulative inductive/capacitive ratio against EPDK thresholds (20%/15%) throughout the month. An email alert is sent when the threshold is approached.
Does the PM5350 connect via Ethernet or RS-485?
The PM5350 supports built-in Modbus TCP (Ethernet RJ-45) and Modbus RTU (RS-485). The 6S Field Agent can read both; Ethernet is preferred for lower latency and easier network management.
How frequently is PM5350 data read?
The read interval is configured per device and line speed; hourly and daily summaries are produced automatically. Even if internet is lost, the Field Agent keeps data in a local buffer for 30 days.

Integrate Into Your System

Request a demo; our experts will manage the Schneider Electric PM5350 integration process.

Integrate Into Your System

Explore the system with your own data in a demo session.