⚡ Modbus TCP Integration Guide

DSE 8610/8620

Deep Sea Electronics DSE 8610/8620 Genset Control Module — Real-time power, energy and alarm monitoring via Modbus TCP protocol with 6S Teknoloji.

All Devices →

What Data Do We Read?

Engine Speed (RPM)RPM
Battery VoltageV
Coolant Temperature°C
Oil PressurekPa
Generator Voltage L1V
Generator Voltage L2V
Generator Voltage L3V
Generator FrequencyHz
Total Active PowerkW
Power Factor-
Running Hourshours
Fuel Level%

How to Connect to 6S Teknoloji

1

Physical Connection

Connect the device to the RS-485 or Ethernet network. Configure Slave ID and baud rate from the device front panel or web interface.

2

Add Device in 6S Teknoloji

From the 6S web panel click "New Device". Select DSE 8610/8620 from the template list — the register map loads automatically.

3

Live Monitoring

The Field Agent tests the connection; the first readings appear on the dashboard shortly. Alarm thresholds are configured.

What Can You Monitor?

  • Engine speed (RPM), temperature, oil pressure
  • Battery voltage and charge status
  • Generator L1/L2/L3 voltage and current
  • Total active power (kW) and energy (kWh)
  • Running-hours counter and fuel level
  • Fault codes and alarm status
  • Automatic start/stop (ATS) event log
  • Periodic test-run tracking

Why Is Generator Monitoring Critical?

🏥

Hospitals

Generator start delay is critical in operating theatres and ICUs. 6S Teknoloji reports low-battery and low-fuel alarms in advance.

🏢

Data Centres

Generator active power tracking is essential for PUE calculation. The running-hours log automates maintenance planning.

🏭

Factories

During a production line outage, generator load capacity adequacy is visible instantly. The overload alarm prevents critical machine loss.

Frequently Asked Questions

How does the DSE 8610 connect to 6S Teknoloji?
The DSE 8610/8620 has built-in Modbus TCP support. The DSE Ethernet port connects to the Field Agent over the LAN; once the device template is selected, the connection parameters and register map load automatically.
Can generator fuel level be tracked?
Yes. The DSE module reports fuel level as a percentage. A threshold alarm is configured in 6S Teknoloji (below 20% is critical); email notification is sent automatically.
Are generator ATS transitions logged?
Yes. DSE's event log records and 6S Teknoloji's alarm engine work together. Grid loss, generator start, synchronisation, and return-to-grid events are recorded with timestamps.
Can UPS and generator be monitored together in a hospital?
Yes. 6S Teknoloji monitors UPS (SNMP/Modbus) and generator (DSE) devices together within the same project. The critical power chain is visible on a single dashboard: grid → UPS → generator → load.

Integrate Into Your System

Request a demo; our experts will manage the DSE 8610/8620 integration process.

Integrate Into Your System

Explore the system with your own data in a demo session.